Skip Navigation
Skip to contents

J Trauma Inj : Journal of Trauma and Injury

OPEN ACCESS
SEARCH
Search

Search

Page Path
HOME > Search
2 "Humeral fractures"
Filter
Filter
Article category
Keywords
Publication year
Authors
Case Report
Humeral intramedullary nail bending following trauma: a case report
Siem A. Willems, Alexander P. A. Greeven
J Trauma Inj. 2023;36(1):65-69.   Published online June 17, 2022
DOI: https://doi.org/10.20408/jti.2022.0002
  • 2,355 View
  • 38 Download
AbstractAbstract PDF
The surgical approach for humeral implant failure can be challenging due to neurovascular anatomy and the possible necessity of osteosynthesis removal. We present a rare case of humeral nail bending after secondary trauma in a patient with preexistent nonunion of the humerus after intramedullary nailing. During revision surgery, the nail was sawed in half and the distal part was removed, followed by plate osteosynthesis with cable fixation to achieve absolute stability. The patient regained a full range of motion 1 year after surgery, and complete healing of the fracture was seen on imaging.
Summary
Original Article
Aseptic Humeral Nonunion: What Went Wrong? What to Do? A Retrospective Analysis of 20 Cases
Jinil Kim, Jae Woo Cho, Won Tae Cho, Jun Min Cho, Namryeol Kim, Hak Jun Kim, Jong Keon Oh, Jin Kak Kim
J Trauma Inj. 2016;29(4):129-138.   Published online December 31, 2016
DOI: https://doi.org/10.20408/jti.2016.29.4.129
  • 3,217 View
  • 44 Download
AbstractAbstract PDF
PURPOSE
Due to recent advances in internal fixation techniques, instrumentation and orthopedic implants there is an increasing number of humeral shaft fracture treated operatively. As a consequence, an increased number nonunion after operative fixation are being referred to our center. The aim of this study is to report the common error during osteosynthesis that may have led to nonunion and present a systematic analytical approach for the management of aseptic humeral shaft nonunion.
METHODS
In between January 2007 to December 2013, 20 patients with humeral shaft nonunion after operative procedure were treated according to our treatment algorithm. We could analysis x-rays of 12 patients from initial treatment to nonunion. In a subgroup of 12 patients the initial operative procedure were analyzed to determine the error that may have caused nonunion. The following questions were used to examine the cases: 1) Was the fracture biology preserved during the procedure? 2) Does the implant construct have enough stability to allow fracture healing? RESULTS: In 19 out of 20 patients have showed radiographic evidence of union on follow up. One patient has to undergo reoperation because of the technical error with bone graft placement but eventually healed. There were 2 cases wherein the treatment algorithm was not followed. All patients had problems with mechanical stability, and in 13 patients had biologic problems. In the analysis of the initial operative fixation, only one of 12 patients had biologic problems.
CONCLUSION
In our analysis, the common preventable error made during operative fixation of humeral shaft fracture is failure to provide adequate stability for bony union to occur. And with these cases we have demonstrated a systematic analytic management approach that may be used to prevent surgeons from reproducing the same fault and reduce the need for bone grafting.
Summary

J Trauma Inj : Journal of Trauma and Injury